引用本文: | 商亮亮,陆智林,文传博,邱爱兵.基于规范变量残差的化工过程微小故障检测与诊断[J].控制理论与应用,2021,38(8):1247~1256.[点击复制] |
SHANG Liang-liang,LU Zhi-lin,WEN Chuan-bo,QIU Ai-bing.Canonical residual based incipient fault detection and diagnosis for chemical process[J].Control Theory and Technology,2021,38(8):1247~1256.[点击复制] |
|
基于规范变量残差的化工过程微小故障检测与诊断 |
Canonical residual based incipient fault detection and diagnosis for chemical process |
摘要点击 2740 全文点击 670 投稿时间:2020-09-11 修订日期:2021-01-08 |
查看全文 查看/发表评论 下载PDF阅读器 |
DOI编号 10.7641/CTA.2021.00614 |
2021,38(8):1247-1256 |
中文关键词 规范变量残差 加权平均统计量 微小故障 化工过程 贡献图 故障检测 故障诊断 |
英文关键词 canonical residual weighted average statistics incipient fault chemical process contribution plot fault detection fault diagnosis |
基金项目 国家自然科学基金项目(61973176, 61973209), 江苏省六大人才高峰项目(XYDXX–091), 南通市民生科技重点项目(MS22020030)资助. |
|
中文摘要 |
微小故障因其幅值低而易被噪声和过程扰动所掩盖, 并且会随时间慢慢演变成过程中的严重故障. 因此,
微小故障的检测和诊断变得越来越重要. 为了更有效地监测和诊断微小故障, 提出了基于规范变量残差的化工过程
微小故障检测和诊断方法. 首先, 对Hankel矩阵执行奇异值分解来获得主元和残差空间并根据过去和未来数据的差
异, 求得两个不同的规范变量残差d1, d2. 其次, 考虑数据的时间序列特性, 提出了基于规范变量残差的两个加权平
均统计量WD1, WD2及其控制限, 进行故障检测; 然后, 计算出各个统计量的归一化贡献并绘制二维贡献图, 进行故
障诊断. 最后, 在连续搅拌釜式反应器(CSTR)过程中进行两种微小故障的应用研究. 结果表明, 与传统的统计量T2,
Q以及规范变量差异分析(CVDA)中统计量D相比, 基于规范变量残差的加权平均统计量WD1, WD2不仅能够及时
检测到微小故障, 而且在故障检测率和诊断率方面, 均有不同程度的提高. |
英文摘要 |
Incipient faults can be easily submerged by noise and process disturbance because of their low amplitudes,
and will gradually evolve into serious faults in the process over time. Therefore, incipient faults detection is increasingly
becoming more and more important. To monitor and diagnose incipient faults more efficiently, detection and diagnosis
of incipient faults for chemical processes based on canonical residuals are proposed. First, singular value decomposition
is performed on the Hankel matrix to obtain state space and residual space. Next, according to the difference of past and
future data, two different canonical residuals d1, d2 are obtained. Then, considering the time series characteristics of the
data, two weighted average statistics WD1, WD2 based on canonical residual and its control limit can be determined for
fault detection. Then, the normalized contribution of each statistic is calculated and the two-dimensional contribution plots
are drawn to perform fault diagnosis. Finally, the application of two kinds of incipient faults in the continuous stirred tank
reactor (CSTR) was studied, the results show that compared with the conventional statistics T2, Q and the statistic D in
CVDA those weighted average statistics based on canonical residual can not only detect incipient faults in time, but also
improve the fault detection rates and fault diagnosis rates to varying degrees. |
|
|
|
|
|